Gold Member Since 2015
Audited Supplier
Luoyang Asian Sun Industrial Group Co., Ltd.

ACSR Conductor, AAC Conductor, ABC Conductor manufacturer / supplier in China, offering Overhead Transmission Line 2/0 AWG ACSR Bare Conductor, Fire Resistance Waterproof House Building PVC Insulation Electric Copper Wire, 11kv Oil Cooled Oil-Immersed Power Transformer (250kVA) and so on.

(/ )

Supplier Homepage Product cables aerial bundle cable Overhead Transmission Line 2/0 AWG ACSR Bare Conductor

Overhead Transmission Line 2/0 AWG ACSR Bare Conductor

Purchase Qty.:
(Meters)
10,000-49,999 50,000+
FOB Unit Price: US $0.6 US $0.5
Purchase Qty. (Meters) FOB Unit Price
10,000-49,999 US $0.6
50,000+ US $0.5
Get Latest Price
Port: Qingdao, China
Production Capacity: 70000m/Day
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: ACSR01-E
  • Voltage: Low and Medium Voltage Cable
  • Insulation Material: None
  • Material Shape: Round Wire
  • Certification: ISO, CCC, CE
  • Brand: Dayuan
  • Brand Name: Dayuan
  • Cross Section Area: 10/2-800/100
  • Certificate: ISO9001,CCC,ASTM, BS, DIN, IEC, CSA
  • Packing Details: Wooden Drum
  • Usage: Overhead, Power Transmission Line
  • Transport Package: Simple Roll, Plastic Drum/Reel, Wooden Pallet/Box
  • Origin: Henan, China
  • Application: Construction, Overhead, Power Station
  • Current: DC Cable
  • Sheath Material: None
  • Wire Core Material: Aluminium Cable Steel Reinforced
  • Model: ACSR
  • Model Number: ACSR
  • Conductor: Aluminium Conductor Steel Reinforced
  • Core: Aluminium Cable Steel Reinforced
  • Type of Conductor: Stranded
  • Place of Origin: Henan, China
  • Trademark: Dayuan
  • Specification: ACSR
  • HS Code: 76141000
Product Description
Overhead Transmission Line #2/0 AWG ACSR Bare Conductor

Specifications

Overhead Transmission Line #2/0 AWG ACSR Bare Conductor
1.18 years factory product 
2.good feature 
3.delivery fast
ACSR,AAC,AAAC,ASCSR&ACAR conductor widely used in power transmission lines with various voltage levels.
 

Application:
Used as bare overhead transmission conductor and as primary and secondary distribution conductor and messenger support.ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
 
Quality:
Production accroding to ASTM-B232,BS215-2,and IEC60189,DIN48201.
 
Material:
Conductor:AL1350  aluminum
Steel core:G1A or G2A steel wire
                 Galvanized steel reinforced 
 
Working Conditions:
Ambient temperature:Above -20°C 
Working temperature:Not exceed 80°C
Laying bending radius:Not less than 30 times the cables outer diameter
 
Standards:
ASTM-B232   Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2       Aluminium conductors steel-reinforced -For overhead power transmission
DIN48204       Steel reinforced aluminum stranded conductors
IEC209           Aluminum stranded conductor steel reinforced
Customized type available.
 
ACSR Codes : 
 
Code Name from ASTM-B232:

Code Name from ASTM-B232
ThrasherBluejayGannetFlickerGuinea
KiwiCurlewFlamingoPelicanLeghorn
BluebirdOrtolanEgretLarkQuail
ChukarTanagerScoterIbisMinorca
FalconCardinalGrosbeakBrantRaven
LapwingRailRookChickadee 
ParrotCatbirdSwiftOriolePetrel
NuthatchCanaryKingbirdLinnetRobin
PloverRuddyTealMerlinGrouse
BobolinkMallardWoodDuckOstrichSparate
MartinCondorSquabPartridgeSparrow
DipperTernPeacockWaxwingSwanate
PheasantDrakeEaglePenguinSwan
BitternCuckooDoveCochin.
SkylarkCootParakeetBrahmaTurkey
GrackleRedwingOspreyDorking 
BuntingStarlingHenDotterel 
FinchStiltHawkPigeon 

Code Name from BS215-2:

Mole
RacoonWolfDeer
SquirrelOtterCaracalZebra
GopherCatLynxEik
WeaselHareJaguarCamel
FoxDogPantherMoose
FerretHyenaLion 
RabbitLeoperdBear 
MinkCoyotteGoat 
ShunkCongarSheep 
BeaverTigerAntilope 
HorseDingoBizon 

 
Standards:

ASTM-B232   Standard specification for Concentric-Lay-Stranded Aluminum 1350 Conductors
BS215-2       aluminum conductors steel-reinforced -For overhead power transmission
DIN48204       Steel reinforced aluminum stranded conductors
IEC209           Aluminum stranded conductor steel reinforced

Customized type available.

ACSR Technical Characteristics Based on Standard BS 215-2
Code nameNominal aluminum areaStranding and wire diameterSectional area of aluminumTotal sectional areaApprox. overall diameterApprox. massCalculated D.C. resistance at 20oCCalculated breaking load
AlSteel
mm2No./mmmm2mm2mmkg/kmΩ/kmkN
RABBIT506/3.351/3.3552.8861.710.052140.542618.35
DOG1006/4.727/1.57105118.514.153940.273332.7
WOLF15030/2.597/2.59158.1194.918.137260.182869.2
DINGO15018/3.351/3.35158.7167.516.755060.181535.7
LYNX17530/2.797/2.79183.4226.219.538420.157679.8
ZEBRA40054/3.187/3.18428.9484.528.6216210.0674131.9
Overhead Transmission Line 2/0 AWG ACSR Bare Conductor
Overhead Transmission Line 2/0 AWG ACSR Bare Conductor
Overhead Transmission Line 2/0 AWG ACSR Bare Conductor
Send your message to this supplier
Avatar
Miss Emily
*From:
To: Miss Emily
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now